SPIN TROUBLE
Check the S.PRESSURE SWITCH ASSEMBLY or HOSE (Pressure). If the problem is on the S.PRESSURE SWITCH ASSEMBLY or the HOSE, replace the S.PRESSURE SWITCH ASSEMBLY or the HOSE.
Check on the spinning, is the frequency of the water level 248 or more. The frequency can be
Rinse Spin
checked by pressing the Rinse and Spin buttons at the same time on the program.
NO
YES
When pressing Rinse, Spin and POWER buttons at the same time after power off, press the Start/Pause YES
Rinse Spin
Normal
button 2 times, is the drum spinning at low speed?
NO
(2) (1)
Is it disconnected, or disassembled? [Red:3pin (1), NA:4pin (2)]
YES
Correct the connector.
NO
Check the motor connector, Is the resistance of the terminal same as the figure?
NO
MOTOR TERMINAL (1)
(1)
Replace the STATOR ASSEMBLY (4417FA1994E)
Resistance of terminal: About 5 10
YES
Replace the MAIN PWB ASSEMBLY
29
|
|
 |
> |
|